Gas rating means timing how much gas an appliance burns at full rate, then turning that into a heat input in kW. Enter your metric meter readings, or the time for one turn of the imperial test dial, and this calculator gives the gas rate in m³/h and the gross and net heat input in kW. Compare the result with the manufacturer’s data plate or instructions.
Work out the gas rate
This calculator is a guide. Always follow the appliance manufacturer’s instructions.
What is the gas rate calculation formula?
The calculator uses these formulas and figures for UK natural gas. You can check any result by hand.
Imperial: gas rate (ft³/h) = dial size × revolutions × 3600 ÷ seconds
Imperial to metric: m³/h = ft³/h × 0.0283168
Gross heat input (kW) = m³/h × CV ÷ 3.6
Net heat input (kW) = gross kW ÷ 1.11
- CV is the calorific value of the gas in MJ/m³. The calculator starts at 39.5 MJ/m³, a typical figure for UK natural gas. The actual figure varies a little by area and by day, and your gas bill shows the one used. Some older tables use 38.7 MJ/m³. Change the box to use a different figure.
- Dividing by 3.6 turns MJ per hour into kW, because 1 kWh is 3.6 MJ.
- Dividing by 1.11 turns gross into net for natural gas. Gross includes the heat in the water vapour in the flue gases, net does not. Boiler instructions often quote the net heat input, so check which one the data plate gives.
- 1 ft³ = 0.0283168 m³.
Worked example (metric): the meter moves from 1234.567 to 1234.617 in 120 seconds. That is 0.050 m³, so the gas rate is 0.050 × 3600 ÷ 120 = 1.50 m³/h. Gross heat input is 1.50 × 39.5 ÷ 3.6 = 16.46 kW, and net is 16.46 ÷ 1.11 = 14.83 kW.
Worked example (imperial): a 1 ft³ test dial takes 60 seconds for one revolution. That is 60 ft³/h, or 60 × 0.0283168 = 1.699 m³/h. Gross heat input is 1.699 × 39.5 ÷ 3.6 = 18.64 kW, and net is 16.79 kW.
How do you gas rate a boiler?
The general method is the same for most appliances. Always follow the manufacturer’s instructions for the appliance in front of you.
- Turn off every other gas appliance in the property, so the meter only measures the one you are testing.
- Run the appliance at its full rate. Many boilers have a service or test mode for this; the instructions say how. Let it run for a few minutes to settle.
- Time the meter. On a metric meter, write down the full reading including the red decimals, time exactly 2 minutes (120 seconds), and write down the reading again. On an imperial meter, time one full revolution of the test dial and note the dial size.
- Work out the gas rate and heat input with the calculator above.
- Compare it with the manufacturer’s figures. Check the result against the heat input or gas rate on the data plate or in the instructions, and whether they quote gross or net. If it is well off, check the inlet and burner pressures and follow the manufacturer’s guidance before going further.
- Record it. Put the gas rate on your service record or gas safety record with the other readings.
Where do I record the gas rate on the report?
In Maintivo, the Boiler Gas Safety Record form has a gas rate field in its combustion analysis section, next to the analyser used, inlet pressure, CO, CO₂, the CO/CO₂ ratio, O₂ and flue gas temperature. You fill it in on site, add photos and both signatures, and a branded PDF with your logo and Gas Safe number is ready before you leave. The iPhone app works with no signal and uploads later, and Android phones and tablets use the web app. See the boiler service record app and the gas engineer app.
Your first report is free to fill in. To keep making reports and to export and send PDFs you need a plan, from £34.99 a month, with 14 days free. See pricing.
Questions about gas rating
On a metric meter, take the gas used in m³ over a timed period, multiply by 3600 and divide by the seconds timed. That gives m³/h. Multiply by the calorific value (about 39.5 MJ/m³) and divide by 3.6 to get the gross heat input in kW, then divide by 1.11 for net.
On a metric meter, 2 minutes (120 seconds) is the usual period, with the full reading including the red decimals written down at the start and the end. On an imperial meter, time one full revolution of the test dial.
Gross heat input counts all the heat in the gas, including the heat carried away in the water vapour in the flue gases. Net leaves that out, so it is lower. For natural gas, net is gross divided by about 1.11. Check which one the manufacturer quotes before you compare.
The calculator starts at 39.5 MJ/m³, a typical figure for UK natural gas. The actual figure varies a little by area and by day, and the gas bill shows the one used. You can change it in the calculator.
Check you timed it with every other appliance off and the appliance at full rate, then check the readings and the sums. If it is still well off, check the inlet and burner pressures and follow the manufacturer's instructions for that appliance.
Put the gas rate on the record before you leave
Your first report is free to fill in, with no card and no training day. Run a real job through it and see.